Close Window
High Acoustics
Product has NRC (Noise Reduction Coefficient) of 0.65 or greater and/or AC (Articulation Class) of 170 or greater.
Fire Resistance
Available in fire-resistive options (Fire Guard); tested in specific UL floor/ ceiling or roof/ ceiling construction design assemblies.
Scrubability
Withstands up to 150 scrub cycles using a scrubability tester as per ASTM D 2486
HumiGuard Max
Maximum humidity resistance, Including outdoor applications.
HumiGuard Plus
Superior sag resistance, recommended for areas subject to high humidity, up to standing water and outdoor applications.
Washability
Offers superior wash resistance without compromising panel finish integrity, using a washability tester as per ASTM D 4828
Soil Resistance
Excellent resistance to dirt and/or grease; some products meet acceptance criteria like USDA and/or Class 100 Clean Room
Impact Resistance
Excellent resistance to surface impact based on Falling Ball test - Modified ASTM D 1037
Scratch Resistance
Excellent resistance to surface scratching, scuffing or chipping based on Hess Rake test
High Light Reflectance